Vortex flow meter - IBR approved Steam Flow Meter
Model No ::
VRTProduct Specification ::
BROILTECH Vortex flow meter is approved by IBR ( indian boiler regulation) Director of boiler, goverment of india for measuring Steam and water for boiler application,
Broil sensotek industries Vortex Flowmeter bases on Karman vortex street Principal for detection and metering the liquid, gas and steam. It is widely used in Petroleum, chemical, metallurgy, heat supply
industry, etc.
for steam and gas application available with pressure and temperature compensating,
1) Technical Specification :
Process media : Gas, liquid, air, steam, vapor
Enclosure : 1Cr18Ni9Ti
Accuracy : +/- 0.5 for liquied,
: 1% for gas and steam
Repeatability : 0.2%
Flow range: Liquid:0.4-7.0m/s;
:Gas:4.0-60.0m/s;
:Steam:5.0-70.0m/s
Maximum working pressure: 6 MPa
Fluid &Ambient temperature: -40 to 350 Deg. C
Connection: Thread (M/F) or flange
2) DISPLAY
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row. OR 24 v dc
display mode:
Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
Pressure, temperature reading
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
3) output : 3 wire pulse
: 2 wire 4 to 20 mA
: RS-485
: HART
Measuring ranges for liquid : water
Flow rate: m3/hour
Line size |
Minimum flow rate |
Maximum flow rate |
O/P HZ range |
Temp. |
15 |
1 |
6 |
90-900 |
25°C |
20 |
1.2 |
8 |
40-600 |
25°C |
25 |
2 |
16 |
35-400 |
25°C |
32 |
2.2 |
20 |
20-250 |
25°C |
40 |
2.5 |
25 |
10-240 |
25°C |
50 |
3.5 |
35 |
8-190 |
25°C |
65 |
6 |
60 |
7-150 |
25°C |
80 |
13 |
130 |
6-110 |
25°C |
100 |
20 |
200 |
5-90 |
25°C |
125 |
30 |
300 |
4.5-76 |
25°C |
150 |
50 |
500 |
3.58-60 |
25°C |
200 |
100 |
1000 |
3.2-48 |
25°C |
250 |
150 |
1500 |
2.5-37.5 |
25°C |
300 |
200 |
2000 |
2.2-30.6 |
25°C |
Measuring ranges for gas : density : 1.12, and pressure 1 bar
Flow rate: m3/hour
Line size |
Minimum flow rate |
Maximum flow rate |
O/P HZ range |
Temp. |
15 |
5 |
30 |
460-3700 |
25°C |
20 |
6 |
50 |
220-3400 |
25°C |
25 |
8 |
60 |
180-2700 |
25°C |
32 |
14 |
100 |
130-1400 |
25°C |
40 |
18 |
180 |
90-1550 |
25°C |
50 |
30 |
300 |
80-1280 |
25°C |
65 |
50 |
500 |
60-900 |
25°C |
80 |
70 |
700 |
40-700 |
25°C |
100 |
100 |
1000 |
30-570 |
25°C |
125 |
150 |
1500 |
23-490 |
25°C |
150 |
200 |
2000 |
18-360 |
25°C |
200 |
400 |
4000 |
13-325 |
25°C |
250 |
600 |
6000 |
11-220 |
25°C |
300 |
1000 |
10000 |
9-210 |
25°C |
Product Features ::
Measuring ranges for Saturated Steam : above 10 bar pressure please contact company
Flow rate: kg/hour
Pressure [Linesize] |
1 |
3 |
5 |
7 |
10 |
15 |
5-30 |
6.5-70 |
8-110 |
10-150 |
12-198 |
25 |
10-120 |
15-250 |
20-400 |
20-500 |
25-700 |
40 |
25-350 |
40-700 |
45-1100 |
50-1400 |
64-1928 |
50 |
48-600 |
65-1200 |
80-2000 |
95-2500 |
111-3340 |
80 |
100-1200 |
150-2500 |
180-4200 |
205-5400 |
250-7232 |
100 |
180-2300 |
250-4800 |
290-7200 |
360-8900 |
425-12400 |
150 |
400-4800 |
550-10000 |
700-16000 |
820-21000 |
980-28500 |
200 |
800-9800 |
1100-20000 |
1200-32000 |
1500-38500 |
1750-53800 |
250 |
1200-14000 |
1800-32000 |
21000-50000 |
2400-61500 |
27500-85000 |
300 |
1800-22000 |
2500-48000 |
30000-70000 |
3500-89000 |
41000-123500 |
Range ::
Flow range: Liquid:0.4-7.0m/s;:Gas:4.0-60.0m/s;
:Steam:5.0-70.0m/s
Product Applications ::
- Pure Water
- Fuel
- Air & Gas
- Steam
- Acid& Chemical