Broil Sensotek Logo

Ultrasonic Clamp on flow meter


clamp on flow meter flow meter clamp on clamp on ultrasonic clamp on sensor

Model No ::

UF

Product Specification ::

Ultrasonic Digital Clamp-on flow meter

 

Advantages:

·         OIML / MID 001 / 2014/32/EC certified

·         digital signal processing, high noise immunity;

·         DN range from 10 mm up to 5000 mm;

·         stable operation in spite of weak signal on aged piping;

·         reliable metering on fluid parameters alteration;

·         easy commissioning;

·         bidirectional flow measurement;

·         clamp-on and wetted transducers;

·         no pressure loss in pipeline;

·         batching mode to measure the dose;

·         multi-beam measuring;

·         up to 4 pipes with one electronic unit;

·         waterproof transducers;

·         ISO 9001:2008 certified.

·          

Measured Media:

·         hot and cold process and potable water;

·         waste water;

·         acids;

·         alkalis;

·         liquid foods.

 Specification:

Parameter

wetted PEA

clamp-on PEA

   

 

Nominal diameter of the pipeline, DN

10 ÷ 5000

50 ÷ 5000

Accuracy, %, with flowrate range from 1:100: 
- single-beam sounding
- two-beam sounding
- four-beam sounding


± 2 
± 1
± 0,5

Flow velocity range, m/s

0.1 ÷ 20

Fluid temperature range, °?

minus 30 ÷ 160

minus 30 ÷ 150

Ambient temperature for transmitter, °?

0 ÷ 50

Maximum pipeline pressure*, MPa/bar

2.5/25

-

Transmitter / transducers protection

IP54/IP68

Measurement data logging, number of records:
- hourly log
- daily log
- monthly log
- programmable
- batching


1440
60
48
14400
512

Power supply, VDC

24

Power consumption, VA

under 12

Transmitter weight, kg

under 3

Transmitter dimensions, mm

250 ÷ 132 ÷ 90

 

 

 *- on request is possible to supply pipeline sections with wetted PEAs designed for up to 25 MPa/250 bar pressure.

 

Outputs:

·         LCD;

·         pulse or logic digital output (up to 8 additional digital outputs on request);

·         RS-232/RS-485 serial interface (ModBus);

·         0-5, 0-20, or 4-20 mA analog output (on request);

·         Ethernet (on request).

 

 

 

Product Features ::

Range ::

Product Applications ::

  • Pure Water
  • Waste Water
  • Fuel
  • Acid& Chemical
  • Heat/BTU
  • Hygienic Liquid

Contact form